Atom GSM Communicator is an Single Input Device which can be used with various devices for notification purposes,Once Triggered the device sends SMS &Call to stored user numbers.
Programming of ATOM GSM Communicator can be Done within few minutes through simple SMS Commands ,The SMS Commands are Listed as below.
Register as ADMIN
First You Need to Register your number as ADMIN,Only ADMIN number can program ATOM.To Register as ADMIN Type 121212 and send SMS to Atom Number (SIM number inserted in ATOM device).
Store User Phone Numbers
Now From Admin Number You can Add upto 4 Users Using commands as in below picture.
Set Alert Condition
Alert condition : Open Alert,Close Alert or Both Alerts.
For example if you have connected Atom using an sensor with door ,if you need Alert when door is opened Set open Alert- ALT 0,If you want alert when door is closed set close alert-ALT C,If you want alert during both open and close set – ALT S.
Set Alert Type
Alert Type: SMS Alert ,Call Alert or Both Alerts.
If you want
only SMS Alert – CS NY
only CALL Alert – CS YN
Both Alerts – CS YY
Set Message
Set 15 Text Message which you wish to receive during alert conditions.
Set Balance Command
Set Balance Command for the SIM inserted in ATOM Device to check Balance when required.
Activation of ATOM
To activate Type ACT and send to Atom Device.
Deactivation of ATOM
To deactivate Type DA and send to Atom device.
Programming of Atom GSM Communicator is Done.You can further Check Status of System,Change admin number,Reset atom if you wish,For those details you can check ATOM user Manual.
The Device can be useful for various Electronics equipments,all you need is Volt free alarm signal from the equipment to trigger the atom device.